Skip to content

Latest commit

 

History

History
106 lines (85 loc) · 4.14 KB

File metadata and controls

106 lines (85 loc) · 4.14 KB

Runtime Configuration and Captive Portal

GlowLight loads network, radio, group and synchronization defaults from NVS at boot. If NVS has no valid record, the values in include/GlowConfig.h are used. If neither source validates, the firmware fails closed with infrastructure WiFi and group communication disabled on fallback channel 1.

Hardware pins, compiled lighting modes, queue sizes and maximum group size remain build-time configuration.

Stored Configuration

The glow.config schema contains:

  • infrastructure WiFi enabled state, SSID, password and hostname

Lamps are usually flashed from one shared configuration, so a hostname left at its default is not unique. Each lamp therefore appends the last three bytes of its MAC, giving names like glowlight-52c82c. It announces the result as Reachable as <name>.local, and that name is also the device name in Home Assistant. A hostname entered in the captive portal belongs to that one lamp and is used as given.

  • ESP-NOW fallback channel
  • secure group communication enabled state and 256-bit group key
  • default follow and publish synchronization policy
  • OTA enabled state and write-only OTA password

The PreferencesConfigStore keeps two CRC-protected slots in the glowcfg NVS namespace. A save writes the older slot with a higher generation and verifies it before reporting success. At boot the highest valid generation wins; a corrupt or partially written slot is ignored as a whole.

NVS persistence does not imply flash encryption. A person with physical flash access can recover stored WiFi, group and OTA credentials unless ESP32 flash/NVS encryption is enabled for the product.

Opening the Portal

The installer can enable the portal and generates an individual WPA2 password. With the feature enabled:

  1. Disconnect power from the lamp.
  2. Hold the lamp button.
  3. Apply power and keep the button held during boot.
  4. Join <hostname>-setup using the generated portal password.
  5. Open http://192.168.4.1/ if the operating system does not open the captive page automatically. The actual address is printed on the serial console.

The portal never opens merely because an infrastructure access point is down and automatically restarts the lamp after ten minutes. It runs in WIFI_AP_STA mode on the configured fallback channel, leaves modem sleep disabled and does not deinitialize ESP-NOW. Existing secure group communication therefore remains available to lamps on the same channel.

An ESP32-C3 has one radio. A peer connected to an infrastructure access point on a different channel cannot communicate with the provisioning lamp until both are again on the same channel.

Configuration API

The portal exposes glow.config/1 only while the physically activated setup AP is running:

GET  /api/config
POST /api/config
POST /api/factory-reset

GET /api/config returns redacted state and a per-boot CSRF sessionToken. WiFi passwords and group keys are never returned. Mutating requests require that token in the X-Glow-Token header. Access authentication is provided by the individual WPA2 portal password; the token prevents cross-origin form submission. An empty password or key field preserves the stored secret.

{
  "api": "glow.config/1",
  "wifi": {
    "enabled": true,
    "ssid": "home",
    "password": "write-only",
    "hostname": "glow-bedroom"
  },
  "radio": {"fallbackChannel": 6},
  "group": {
    "enabled": true,
    "key": "64 hexadecimal characters, write-only",
    "follow": true,
    "publish": true
  },
  "ota": {"enabled": true, "password": "write-only"}
}

Updates are validated and stored atomically, then the lamp restarts. Active WiFi credentials and group keys are never replaced live. Factory reset clears NVS overrides and restarts into the compile-time configuration.

The portal deliberately does not expose Controller::executeControl(). The configuration AP and session token protect provisioning, but are not a general authorization mechanism for lamp control.