41 changes: 41 additions & 0 deletions .github/workflows/ci.yml
Original file line number Diff line number Diff line change
@@ -0,0 +1,41 @@
name: CI

on:
push:
branches: [main, redesign]
pull_request:
workflow_dispatch:

jobs:
hassfest:
name: hassfest
runs-on: ubuntu-latest
steps:
- uses: actions/checkout@v4
- uses: home-assistant/actions/hassfest@master

hacs:
name: HACS validation
runs-on: ubuntu-latest
steps:
- uses: actions/checkout@v4
- uses: hacs/action@main
with:
category: integration
# brands not yet submitted to home-assistant/brands (M3)
ignore: brands

lint-test:
name: Lint & test
runs-on: ubuntu-latest
steps:
- uses: actions/checkout@v4
- uses: actions/setup-python@v5
with:
python-version: "3.13"
- name: Install tools
run: python -m pip install --upgrade ruff pytest
- name: Ruff
run: ruff check custom_components tests
- name: Pytest
run: pytest tests -q
14 changes: 14 additions & 0 deletions .gitignore
Original file line number Diff line number Diff line change
@@ -0,0 +1,14 @@
# macOS
.DS_Store

# Claude Code session/local state
.claude/

# Python
__pycache__/
*.py[cod]
.venv/
venv/
.mypy_cache/
.ruff_cache/
.pytest_cache/
369 changes: 369 additions & 0 deletions DESIGN.md

Large diffs are not rendered by default.

175 changes: 102 additions & 73 deletions README.md
Original file line number Diff line number Diff line change
@@ -1,79 +1,108 @@
# Dimplex WPM – Home Assistant Modbus TCP integration

Custom HACS integration for connecting Dimplex WPM / NWPM heat pump controllers over Modbus TCP. The integration batches Modbus reads through a dedicated async pymodbus client, exposes sensors and binary sensors via a `DataUpdateCoordinator`, builds a device tree (Controller → HC1 → DHW → Smart Grid), and allows writing SG Ready mode as a select entity.

## Dimplex Modbus TCP documentation

Reference specification for Dimplex heat pumps: https://dimplex.atlassian.net/wiki/spaces/DW/pages/3303571457/Modbus+TCP+Anbindung

## Features (v0.1.0)

- Config Flow and Options Flow (UI-first, stored in Config Entries).
- Periodic batch polling of key registers (temperatures, status/lock/fault codes, SG Ready).
- Human-friendly text sensors for status, lock, fault, and SG Ready.
- Diagnostic binary sensors for `fault_active` and `lock_active`.
- Controller info diagnostic sensor with host/port/unit, last update, and capabilities.
- SG Ready mode writable as a select (`Hardware`, `Yellow`, `Green`, `Red`, `Deep Green`) gated by the Options Flow (disabled by default).
- Optional toggles for write entities and future EMS/BMS features.

### Entities

| Type | Entity | Register | Notes |
| --- | --- | --- | --- |
| sensor | controller_info | — | Attributes: host/port/unit_id, last_update, failure counter, capabilities |
| sensor | outdoor_temperature | 1 (int16, 0.1°C) | Temperature °C |
| sensor | return_temperature | 2 (int16, 0.1°C) | Temperature °C |
| sensor | return_setpoint_temperature | 53 (int16, 0.1°C) | Temperature °C |
| sensor | flow_temperature | 5 (int16, 0.1°C) | Temperature °C |
| sensor | dhw_temperature | 3 (int16, 0.1°C) | Temperature °C |
| sensor | status_code / status | 103 | Diagnostic + mapped text |
| sensor | lock_code / lock | 104 | Diagnostic + mapped text |
| sensor | fault_code / fault | 105 | Diagnostic + mapped text |
| sensor | sensor_error_code / sensor_error | 106 | Diagnostic + mapped text |
| sensor | sg_ready_code / sg_ready_state | 5167 | Diagnostic code + text |
| binary_sensor | fault_active | derived | `True` when fault code ≠ 0 |
| binary_sensor | lock_active | derived | `True` when lock code ≠ 0 |
| select | sg_ready_mode | 5167 | Writable: Hardware / Yellow / Green / Red / Deep Green |
# Dimplex WPM — Home Assistant (Modbus TCP)

Custom HACS integration for Dimplex **WPM / NWPM** heat-pump controllers over
Modbus TCP. It is driven by a single canonical register table, groups entities
under a device tree, and — crucially — ships a **native estimation engine** so
installations **without** an electricity meter or heat meter still get power,
COP, heat-output, flow and energy figures.

> Reference spec: Dimplex NWPM Modbus TCP —
> https://dimplex.atlassian.net/wiki/spaces/DW/pages/3303571457/Modbus+TCP+Anbindung

## Highlights

- **Register-table driven** (`registers.py`): one source of truth → ~100 read
entities. Status/lock/fault/sensor-error register **addresses are firmware-
version-aware** (H / J / L / M).
- **Device profiles** (`profiles.py`): LAK9 calibration (Hz→W LUT, EN14511 COP
table) + a generic profile. Community models = one new profile file.
- **Capabilities** (per install): electric meter, heat meter, external flow
sensor, inverter frequency. Declared in the setup wizard with an auto-hint
probe of the device.
- **Measurement source matrix** — each power/heat/flow/COP/energy value is
`measured` (read from a meter register) when the hardware exists, otherwise
`estimated` by the engine. Entities carry a `source` attribute.
- **Native energy** (kWh, `total_increasing`, restored across restarts) ready
for the Energy Dashboard; measured heat-meter counters use the digit-group
combination from the spec.
- **Live calibration** of the estimation engine via `number` entities (write to
HA, not the pump).
- **Control behind a gate** (`enable_control`, off by default): setpoints
(`number`) and modes (`select`, incl. SG Ready) write to the pump, range-
validated.
- **Importable dashboards** (`dashboards/`), built-in cards only.

## Device tree

`Dimplex WPM` (controller) → `Heating circuit 1`, `Domestic hot water`,
`Heat source`, `Analytics`, and — when present — `Heating circuits 2/3`,
`Swimming pool`, `Ventilation`, `Solar`, `Passive cooling`.

## Installation (HACS custom repository)

1. In HACS → Integrations → ⋮ → **Custom repositories**, add this repo URL and select **Integration**.
2. Install “Dimplex WPM”.
3. Restart Home Assistant.
4. Go to Settings → Devices & Services → **Add Integration** → search for “Dimplex WPM.
1. HACS → Integrations → ⋮ → **Custom repositories**add this repo URL, type
**Integration**.
2. Install **Dimplex WPM**, restart Home Assistant.
3. Settings → Devices & Services → **Add Integration** → **Dimplex WPM**.

## Configuration

Config Flow fields:

- **Host** (IP/DNS)
- **Port** (default `502`)
- **Unit ID** (default `1`)
- **Scan interval** (seconds, default `30`)
- **Timeout** (seconds, default `5`)
- **Software version** (`H`, `J`, `L`, `M`)
- **Register bank strategy**: `auto` (try input then holding), `holding`, or `input`

Options Flow:

- **Scan interval** override.
- **Enable write entities** (gate for SG Ready select, default **off**).
- **Enable EMS entities**, **BMS outdoor temp**, **external lock** (placeholders for upcoming releases).

## How it works

- A dedicated async `pymodbus` TCP client manages connection/reconnect and register reads/writes.
- `DataUpdateCoordinator` batches reads into contiguous ranges for efficiency.
- Entities are thin wrappers reading from `coordinator.data` (`raw` and `derived` dicts).
- SG Ready writes call `write_register` on register `5167`, mapping friendly strings to numeric codes.
- Register addresses match the Dimplex documentation (1-based); the integration applies the Modbus client offset automatically.

## Development roadmap

- v0.1.0 (this repo): MVP read + SG Ready write.
- v0.2.0: EMS/power registers, external lock, BMS outdoor temperature number entity.
- Additional status/lock/fault map coverage based on field feedback.

## Dashboard example

A sample Lovelace board is available in `dimplex_dashboard.yaml` demonstrating status and temperature graphs. Import it into a manual dashboard to start visualizing the entities.
**Step 1 (connection):** Host, Port (502), Unit ID (1), heat-pump **profile**
(LAK9 / generic), **software version** (H/J/L/M, default M), scan interval,
timeout.

**Step 2 (modules & metering):** which optional modules exist (HC2/3, pool,
ventilation, solar, passive cooling) and which meters are present (electric /
heat / flow sensor / inverter frequency). Suggestions are pre-filled from a
device probe; without a meter the value is estimated.

**Options** (re-configurable): scan interval, modules, capabilities, flow-sensor
entity, include reverse-engineered registers, and **Enable control / write
entities** (the write gate).

## Removal

Settings → Devices & Services → Dimplex WPM → ⋮ → **Delete**. All entities and
devices are removed with the config entry. To uninstall the code, remove the
integration from HACS (or delete `custom_components/dimplex_wpm/`) and restart.

## Dashboards

Import `dashboards/dimplex_wpm.yaml` (Settings → Dashboards → New dashboard →
Edit → raw configuration editor → paste). Five views: Overview, Heat & Energy,
History, Control (only useful with the write gate on), Diagnostics/Calibration.

Entity ids follow the default-naming scheme documented in
[`spec/ENTITY_IDS.md`](spec/ENTITY_IDS.md) — if you renamed entities, adjust the
ids. The dashboards use only built-in cards; `apexcharts-card` is an optional
upgrade for the Energy view (see `spec/DASHBOARD_DESIGN.md`).

For the Energy Dashboard, add **one** electrical-energy entity
(`sensor.analytics_electrical_energy_est`, or the measured equivalent with an
electric meter). The thermal (heat-delivered) sensors are not electricity — do
not add them as grid consumption.

## Notes & limitations

- **Setpoint scaling** for some writable registers is assumed whole-°C (matches
the working YAML) and should be **verified on a real device** before relying
on writes. The control gate is off by default and writes are range-validated.
- **Climate** thermostats for HC1 and DHW are available behind the control gate
(current temperature from a read sensor, target = the writable setpoint).
- Estimation requires the LAK9 profile (calibration) + the inverter-frequency
register; the generic profile yields read-only entities.

## Status / design

This is the redesign branch. Architecture and rationale live in
[`DESIGN.md`](DESIGN.md); the verified register map in
[`spec/REGISTERS.md`](spec/REGISTERS.md). CI runs hassfest, HACS validation,
ruff and pytest.

**Quality scale** (self-assessment in
[`custom_components/dimplex_wpm/quality_scale.yaml`](custom_components/dimplex_wpm/quality_scale.yaml)):
most of Bronze and Silver is met (config flow, unload, error handling,
parallel-updates, diagnostics, entity translations, async client). Open items
before formally claiming a tier: HA-runtime test coverage (config flow +
coordinator), `entry.runtime_data` migration, and Gold polish (icon
translations, reconfigure flow, exception translations).
79 changes: 52 additions & 27 deletions custom_components/dimplex_wpm/__init__.py
Original file line number Diff line number Diff line change
@@ -1,4 +1,4 @@
"""Init file for Dimplex WPM integration."""
"""Dimplex WPM integration."""

from __future__ import annotations

Expand All @@ -9,57 +9,86 @@
from homeassistant.core import HomeAssistant

from .const import (
CONF_ENABLE_BMS_TEMP,
CONF_ENABLE_EMS,
CONF_ENABLE_EXTERNAL_LOCK,
CAPABILITY_CONF_MAP,
CONF_ENABLE_WRITE_ENTITIES,
CONF_REGISTER_STRATEGY,
CONF_ENABLED_MODULES,
CONF_FLOW_SENSOR_ENTITY,
CONF_INCLUDE_RE_REGISTERS,
CONF_PROFILE,
CONF_SCAN_INTERVAL,
CONF_SOFTWARE_VERSION,
CONF_TIMEOUT,
CONF_UNIT_ID,
DEFAULT_ENABLE_WRITE,
DEFAULT_PROFILE,
DEFAULT_SCAN_INTERVAL,
DEFAULT_SOFTWARE_VERSION,
DEFAULT_TIMEOUT,
DEFAULT_UNIT_ID,
DOMAIN,
resolve_capabilities,
resolve_enabled_modules,
)
from .coordinator import DimplexDataUpdateCoordinator
from .modbus_client import DimplexModbusClient
from .profiles import get_profile
from .registers import CAP_INVERTER_FREQ, CORE_MODULES

LOGGER = logging.getLogger(__name__)

PLATFORMS = [Platform.SENSOR, Platform.BINARY_SENSOR, Platform.SELECT]


async def async_setup(hass: HomeAssistant, config: dict) -> bool:
"""Set up via configuration.yaml is not supported."""
return True
PLATFORMS = [
Platform.SENSOR,
Platform.BINARY_SENSOR,
Platform.NUMBER,
Platform.SELECT,
Platform.CLIMATE,
]


async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
"""Set up Dimplex WPM from a config entry."""
hass.data.setdefault(DOMAIN, {})

host = entry.data[CONF_HOST]
port = entry.data.get(CONF_PORT, 502)
unit_id = entry.data.get(CONF_UNIT_ID, DEFAULT_UNIT_ID)
timeout = entry.data.get(CONF_TIMEOUT, DEFAULT_TIMEOUT)
scan_interval = entry.data.get(CONF_SCAN_INTERVAL, DEFAULT_SCAN_INTERVAL)
register_strategy = entry.data.get(CONF_REGISTER_STRATEGY, "auto")
software_version = entry.data.get(CONF_SOFTWARE_VERSION, DEFAULT_SOFTWARE_VERSION)
source = {**entry.data, **entry.options}
host = source[CONF_HOST]
port = source.get(CONF_PORT, 502)
unit_id = source.get(CONF_UNIT_ID, DEFAULT_UNIT_ID)
timeout = source.get(CONF_TIMEOUT, DEFAULT_TIMEOUT)
scan_interval = source.get(CONF_SCAN_INTERVAL, DEFAULT_SCAN_INTERVAL)
software_version = source.get(CONF_SOFTWARE_VERSION, DEFAULT_SOFTWARE_VERSION)

profile = get_profile(source.get(CONF_PROFILE, DEFAULT_PROFILE))

if CONF_ENABLED_MODULES in source:
enabled_modules = resolve_enabled_modules(source)
else:
enabled_modules = frozenset(CORE_MODULES) | profile.default_modules

if any(key in source for key in CAPABILITY_CONF_MAP):
capabilities = resolve_capabilities(source)
else:
capabilities = profile.default_capabilities

include_re = source.get(
CONF_INCLUDE_RE_REGISTERS, CAP_INVERTER_FREQ in capabilities
)
enable_control = entry.options.get(CONF_ENABLE_WRITE_ENTITIES, DEFAULT_ENABLE_WRITE)

client = DimplexModbusClient(host, port, unit_id, timeout)
coordinator = DimplexDataUpdateCoordinator(
hass,
client,
scan_interval=scan_interval,
register_strategy=register_strategy,
software_version=software_version,
enabled_modules=enabled_modules,
capabilities=capabilities,
include_re=include_re,
profile=profile,
flow_sensor_entity=source.get(CONF_FLOW_SENSOR_ENTITY) or None,
enable_control=enable_control,
host=host,
port=port,
unit_id=unit_id,
software_version=software_version,
)

await coordinator.async_config_entry_first_refresh()
Expand All @@ -71,18 +100,14 @@ async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
"port": port,
"unit_id": unit_id,
"software_version": software_version,
"profile": profile.key,
"model": profile.name,
CONF_ENABLE_WRITE_ENTITIES: entry.options.get(
CONF_ENABLE_WRITE_ENTITIES, DEFAULT_ENABLE_WRITE
),
CONF_ENABLE_EMS: entry.options.get(CONF_ENABLE_EMS, False),
CONF_ENABLE_BMS_TEMP: entry.options.get(CONF_ENABLE_BMS_TEMP, False),
CONF_ENABLE_EXTERNAL_LOCK: entry.options.get(
CONF_ENABLE_EXTERNAL_LOCK, False
),
}

entry.async_on_unload(entry.add_update_listener(_async_update_listener))

await hass.config_entries.async_forward_entry_setups(entry, PLATFORMS)
return True

Expand All @@ -97,5 +122,5 @@ async def async_unload_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:


async def _async_update_listener(hass: HomeAssistant, entry: ConfigEntry) -> None:
"""Handle options update by reloading entry."""
"""Reload the entry when options change."""
await hass.config_entries.async_reload(entry.entry_id)
Loading
Loading