225 changes: 64 additions & 161 deletions docs/inverter-setup.md
Original file line number Diff line number Diff line change
Expand Up @@ -2785,180 +2785,83 @@ See the components documentation for details: [Components - Sunsynk Cloud API](c

## Sunsynk

- Copy the Sunsynk template over the top of your `apps.yaml`, and edit for your system.
- Create the following Home Assistant automations:
Predbat can control Sunsynk inverters directly through a single timer slot.
No additional Home Assistant automations or template sensors are required.

```yaml
alias: Predbat Charge / Discharge Control
description: "Turn SunSynk charge/discharge on/off to mirror Predbat"
trigger:
- platform: state
entity_id:
- binary_sensor.predbat_charging
to: "on"
id: predbat_charge_on
- platform: state
entity_id:
- binary_sensor.predbat_charging
to: "off"
id: predbat_charge_off
- platform: state
entity_id:
- binary_sensor.predbat_exporting
to: "on"
id: predbat_discharge_on
- platform: state
entity_id:
- binary_sensor.predbat_exporting
to: "off"
id: predbat_discharge_off
condition: []
action:
- choose:
- conditions:
- condition: trigger
id:
- predbat_charge_on
sequence:
- service: switch.turn_on
data: {}
target:
entity_id: switch.sunsynk_grid_charge_timezone1
- conditions:
- condition: trigger
id:
- predbat_charge_off
sequence:
- service: switch.turn_off
target:
entity_id:
- switch.sunsynk_grid_charge_timezone1
data: {}
- conditions:
- condition: trigger
id:
- predbat_discharge_on
sequence:
- service: switch.turn_on
data: {}
target:
entity_id: switch.sunsynk_solar_sell
- conditions:
- condition: trigger
id:
- predbat_discharge_off
sequence:
- service: switch.turn_off
target:
entity_id:
- switch.sunsynk_solar_sell
data: {}
mode: single
```
### Setup

- Optional: create the following automation to prevent export when the current export price is negative.
- On negative price, it sets Sunsynk to `Zero export to CT` and turns off `switch.sunsynk_solar_sell`
- On positive price, it only turns `switch.sunsynk_solar_sell` back on (it does not restore work mode)
- `grid_export_now` is an attribute of `sensor.predbat_marginal_energy_costs`
On the Sunsynk inverter timer page, configure:

```yaml
alias: "Sunsynk - Negative Export Price Safety"
description: "Set Zero export to CT on negative export price and re-enable solar_sell when price recovers"
trigger:
- platform: template
value_template: >
{{ (state_attr('sensor.predbat_marginal_energy_costs', 'grid_export_now') | float(9999)) < 0 }}
for: "00:02:00"
id: negative_price

- platform: template
value_template: >
{{ (state_attr('sensor.predbat_marginal_energy_costs', 'grid_export_now') | float(-9999)) > 1 }}
for: "00:02:00"
id: positive_price

condition: []
action:
- choose:
- conditions:
- condition: trigger
id: negative_price
sequence:
- service: select.select_option
target:
entity_id: select.sunsynk_work_mode
data:
option: "Zero export to CT"
- service: switch.turn_off
target:
entity_id: switch.sunsynk_solar_sell
| Timer | Time | Grid Charge |
|-------|-------|-------------|
| 1 | 00:30 | Enabled |
| 2 | 23:00 | Disabled |
| 3 | 23:30 | Disabled |
| 4 | 23:30 | Disabled |
| 5 | 23:30 | Disabled |
| 6 | 23:30 | Disabled |

- conditions:
- condition: trigger
id: positive_price
sequence:
- service: switch.turn_on
target:
entity_id: switch.sunsynk_solar_sell
mode: single
```
Only Timer 1 has grid charging enabled. The remaining slots are parked
outside the operating window.

In `apps.yaml`, map Predbat to Timer 1:

```yaml
alias: PredBat - Copy Charge Limit
description: Copy Battery SoC to all timezone (time) slots
trigger:
- platform: state
entity_id:
- number.sunsynk_set_soc_timezone1
to: null
condition: []
action:
- service: number.set_value
data_template:
entity_id:
- number.sunsynk_set_soc_timezone2
- number.sunsynk_set_soc_timezone3
- number.sunsynk_set_soc_timezone4
- number.sunsynk_set_soc_timezone5
- number.sunsynk_set_soc_timezone6
value: "{{ states('number.sunsynk_set_soc_timezone1')|int(20) }}"
mode: single
```
use_timer:
- switch.ss_use_timer_2

- Create the following templates sensors in your `configuration.yaml`:
timed_charge_current:
- number.ss_battery_max_charge_current_2

```yaml
template:
sensor:
- name: "sunsynk_max_battery_charge_rate"
unit_of_measurement: "w"
state_class: measurement
state: >
{{ [8000,[states('input_number.sunsynk_battery_max_charge_current_limit')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min
* states('sensor.sunsynk_battery_voltage')|float]|min }}
timed_discharge_current:
- number.ss_battery_max_discharge_current_2

- name: "sunsynk_max_battery_discharge_rate"
unit_of_measurement: "w"
state_class: measurement
state: >
{{ [8000,[states('input_number.sunsynk_battery_max_discharge_current_limit')|int,states('sensor.sunsynk_battery_discharge_limit_current')|int]|min
* states('sensor.sunsynk_battery_voltage')|float]|min }}
charge_limit:
- number.ss_prog1_capacity_2

- name: "sunsynk_charge_rate_calc"
unit_of_measurement: "w"
state_class: measurement
state: >
{{ [8000,[states('input_number.test_sunsynk_battery_max_charge_current')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min
* states('sensor.sunsynk_battery_voltage')|float]|min }}
charge_rate:
- number.ss_prog1_power_2

- name: "sunsynk_discharge_rate_calc"
unit_of_measurement: "w"
state_class: measurement
state: >
{{ [8000,[states('input_number.test_sunsynk_battery_max_discharge_current')|int,states('sensor.sunsynk_battery_discharge_limit_current')|int]|min
* states('sensor.sunsynk_battery_voltage')|float]|min }}
charge_start_time:
- select.ss_prog1_time_2

charge_end_time:
- select.ss_prog1_time_2

charge_enable:
- select.ss_prog1_charge_2
```

Predbat writes the charge window directly into Timer 1, for example:

- `sensor.predbat_SK_0_charge_start_time = 15:30:00`
- `sensor.predbat_SK_0_charge_end_time = 16:00:00`
- `select.ss_prog1_charge_2 = Allow Grid`

### Why one slot?

Sunsynk timer slots are sequential intervals — each runs until the next
slot's start time — and Sunsynk requires them to be set chronologically.
When Predbat manages all six slots, charge windows that cross midnight can
create overlapping or duplicate start times, leading to unreliable timer
behaviour. Using one dedicated slot avoids this.

This configuration has been running reliably since March 2026, including
midnight-crossing windows, with no issues.

### Alternative: six-slot configuration

Mapping Predbat across all six slots is possible but requires care with
chronological ordering and midnight rollover. If you experience timer
conflicts, use the single-slot method above.

The previous automation-based configuration (using
`binary_sensor.predbat_charging`, `switch.sunsynk_grid_charge_timezone1`
and template sensors) remains valid for users whose setups depend on it.

Note: the standard `utility_meter` block is still required, as it is for
every Predbat installation. This is not Sunsynk-specific.