Solax X3 Hybrid esp8266 modbus-to-influxdb converter

This ESP tool reads the metrics data from the Solax X3 Hybrid Gen4 inverter via modbus and writes it to an InfluxDB.

  • Reads the important metrics data from the Solax inverter modbus input register
  • Stores the metrics in an InfluxDB (in my case hosted on a Raspberry Pi, visualized in a Grafana dashboard)
  • Exposes the same data read-only in the local network as JSON (GET /status) plus a health endpoint (GET /health)
  • Pushes the current grid feed-in surplus to a Nibe heat pump bridge

Polling interval

DATA_POLL_INTERVAL is 1000 ms, but each of the 42 input registers is read in its own Modbus transaction with a busy-wait of at least 25 ms. The effective cycle time is therefore roughly 2-3 seconds, not one second.

Hardware

  • The Solax X3 Hybrid Gen4 inverter provides a modbus RTU (RS485) interface (it is called COM on the inverter)
    • Remark: some older versions of this inverter also supported modbus TCP but since the 4th generation this option was removed (I don't understand why??)
    • The modbus default baudrate for this device is 19200 (8N1, slave ID 1)
  • I used the NodeMCU version of esp8266 (NodeMCU 1.0 / ESP-12E)
  • A RJ45 socket is used for this interface
  • For the RS485 connection on the ESP you need a level converter (in my case I used the MAX485)

Pinning

On the inverter side — RJ45 pinout of the COM port:

RJ45 pin Signal
4 RS485 A
5 RS485 B
6 GND (optional, was not required in my case)

On the ESP side — the MAX485 sits between them:

MAX485 NodeMCU Direction
RO (receiver out) D2 MAX485 -> ESP (RX)
DI (driver in) D1 ESP -> MAX485 (TX)
DE + RE (tied together) D3 ESP -> MAX485 (transmit enable)
A / B — to RJ45 pin 4 / 5 on the inverter

Note that D1/D2 carry the TTL side (RO/DI), not A/B. A/B is the RS485 differential pair going to the inverter.

Configuration

Credentials are not in the repository. Copy the template and fill in your values:

cp project/secrets.h.example project/secrets.h
$EDITOR project/secrets.h

project/secrets.h is gitignored. It holds the WiFi credentials, the static IP, the InfluxDB URL/token/org/bucket and the Nibe bridge URL. Set NIBE_API_URL to "" if you don't have a heat pump to talk to.

Building and flashing

Either open project/project.ino in the Arduino IDE as before, or use the provided Makefile (requires arduino-cli):

make build                                  # compile
make ports                                  # find the board
make flash PORT=/dev/cu.usbserial-0001      # compile + upload
make monitor PORT=/dev/cu.usbserial-0001    # serial log at 115200 baud

Verified toolchain (pinned in project/sketch.yaml):

Component Version
esp8266 core 3.1.2
modbus-esp8266 4.1.0
ESP8266 Influxdb 3.13.2

Data semantics

InfluxDB receives the raw register values, not scaled units. Most registers carry a factor of 0.1 (voltage in 0.1 V, current in 0.1 A, energy in 0.1 kWh; the feedin_energy_* / consum_energy_* counters use 0.01 kWh). The conversion happens in the Grafana dashboard so that the historical series stay consistent. The factor for every register is documented inline in project/project.ino.

REST API

Endpoint Response
GET /status JSON object with the numeric registers from the most recent poll cycle, CORS enabled
GET /health 200 when modbus and InfluxDB are both fine, 503 with a JSON error body otherwise
GET /nibe Current state of the heat pump push
POST /nibe?enabled=true|false Switch the heat pump push on/off, persisted in EEPROM

Heat pump push switch

The push to the Nibe bridge can be toggled at runtime without reflashing. The setting is stored in the emulated EEPROM and survives a reboot and a firmware update. Accepted values are true|false, 1|0 and on|off.

curl http://192.168.1.41/nibe
# {"enabled":true,"configured":true,"active":true}

curl -X POST "http://192.168.1.41/nibe?enabled=false"
# {"enabled":false,"configured":true,"active":false}
Field Meaning
enabled the persisted switch
configured whether NIBE_API_URL is set at all
active enabled && configured — whether a push actually happens

The default on a fresh chip is enabled: true, matching the behaviour before the switch existed. The EEPROM is only written when the value actually changes, so repeated calls cost no flash write cycles.